User Guide

2
GENERAL SPECIFICATIONS - IR1
Klein Tools IR1 is an entry-level infrared thermometer with targeting
laser. It offers a wide measurement range, a 10:1 distance–to-spot
ratio, a targeting laser, and user-selectable from Fahrenheit to Celsius
temperature scales.
Environment: Indoor or outdoor
Operating Altitude: 6562 ft. (2000 m)
Relative Humidity: <85% non-condensing
Operating Temp: 32° to 122°F (0° to 50°C)
Storage Temp: -4° to 140°F (-20° to 60°C)
Measurement Range: -4° to 752°F (-20° to 400°C)
Units: Settable to °F or °C
Emissivity: 0.95 fixed
Optical Resolution (Distance-to-spot): 10:1
Dimensions: 6" x 4.1" x 1.7" (152 x 104 x 43 mm)
Weight: 7.4 oz. (210 g) including battery
Battery Type: 1 x 9V battery
Battery Life: (Estimates assume 9V Zinc-Carbon Battery)
5 hours continuous use w/laser and backlight on.
Display: Backlit LCD with white backlight
Display Resolution: 0.1°F (0.1° C)
Laser: FDA and IEC Class 2
Wavelength: 630 – 670 nm
Max Power: 1mW
Beam Divergence: 1.5mrad
Standards: Certified to IEC EN 61326-1:2013, EN 61326-2-3:2013,
IEC EN 60825-1:2014
Complies with 21 CFR PART 1040.10 and 1040.11
except for deviation pursuant to
Laser notice No.50,dated June 24, 2007
Pollution degree: 2
Drop Protection: 6.6 ft. (2m)
Specifications subject to change.
ENGLISH
MEASUREMENT SPECIFICATIONS
Response Time: <500ms
Data hold: Yes
Spectral Response: 8000-14000nm
≥32
°F
(≥0
°C
) ±4
°F
(±2
°C
) or ±2%, whichever is greater
<32
°F
(<0
°C
)
±(4
°F
+ 0.1
°F
per degree below 32
°F
)
±(2.0
°C
+ 0.1
°C
per degree below 0
°C
)
Repeatability: ±1.0% of reading or ±2°F(±1°C)
(whichever is greater).
Temperature Correction Coefcient:
±0.1°F per °F (±0.1°C per °C), or ±0.2%
of reading (whichever is greater) when ambient temperature is above or
below 70 – 77°F (21 – 25°C).
Specifications subject to change.