FUNCTION BUTTONS
UNITS
10
Press the UNITS button to display amps, watts, and watt-hours information for inputs and outputs. When using both USB and AC outputs, amps will only be display on the circuit
that was initially activated. To cycle to the amp output from the other port, the INFO (12) button must be pushed. The data provided is real-time and will adjust as the load changes
from the device that is plugged into the portable battery.
DISPLAY
11
Press the DISPLAY button to illuminate the LCD for short duration. Press and hold the DISPLAY button to keep LCD illuminated indefinitely. Press and hold the DISPLAY button
again to return to default mode.
INFO
12
Press the INFO button for details on battery performance level. Press button to cycle amps between USB and AC outputs, when both are in use.
DETAILS DISPLAYED ON LCD
BATTERY LEVEL
A
: The battery level is provided by percentage of battery charge corresponding to the number of bars and percentage displayed. The bars in the battery level
correspond to the current state of charge, 0-20%, 21-40%, 41-60%, 61-80%, and all five are lit when charge level is above 81%.
TIME UNTIL EMPTY/FULL
B
:
Provides the user live telemetry data on time to completely charge, or deplete the battery based upon the energy entering or leaving the battery. Please
be aware that this value can adjust multiple times as the energy draw changes from the connected devices. This is evident during initial activation of ports with a connected device.
INPUT
C
: The KTB5 is capable of providing input energy in watts, watt-hr, or amps.
OUTPUT
D
: The display will only provide amp output of the AC port or the DC port, not a combined value. Refer to function button details on how to display amp output from
each port, if both are in use.
COOLING FAN
15
: KTB5 utilizes an internal cooling fan to ensure the product is operating within the appropriate temperature range. The unit, when it experiences a higher output
load, will automatically turn on the fan. During discharge, and possibly charging, the fan may operate intermittently to keep internal temperature within operating range. The fan will
likely start when the AC circuit is activated to ensure proper operation.
OPERATING INSTRUCTIONS
CHARGING KTB5
Only charge unit with provided AC wall charger, Klein Cat. No. 29201.
Charge unit indoors.
Connect the provided AC Wall Charger
14
to the AC Charger input
3
, and allow KTB5 to fully charge prior to use, approx. 9 hours. When charging, the AC Charging Indicator
LED
4
will be illuminated, and the LCD display will provide charge level
A
, along with time until full
B
. The unit is fully charged when the level is 100. It is recommended to
fully charge KTB5 every 3 months to maintain the health of the battery pack.
POWERING / CHARGING DEVICES WITH KTB5
Select the type of outlet required by pressing the USB Output ON/OFF Button
5
or the AC Outlet ON/OFF Button
8
. The outlet port will NOT function until the appropriate button
is pressed to activate the port. When activated, the indicator on the button will illuminate green, indicating that the output(s) are active, and the LCD display will turn on and provide
details on the charging output. Press the ON/OFF button(s) to shut down the output(s) when not in use. The LCD will automatically shut down when no outputs are activated.
KTB5 will enter sleep mode after 90 seconds of inactivity (no output load detected), and will "wake up" when inputting a charging cord or when any button is pressed.
PASS-THROUGH CHARGING
The advanced battery management system of the KTB5 allows it to charge a connected device while the wall charger unit is plugged into the KTB5. The KTB5 is capable of
supporting more output than can be provided by the wall charger input. Therefore, the KTB5 may still be depleting battery capacity depending upon the load required by the
connected device being charged.
OVERLOAD CONDITION
If the LCD displays the overload condition symbol (“OL”); do the following:
Turn off USB ports
5
and AC outlets
8
. The green indicator light will no longer be illuminated when the ports / outlets are turned off.
Disconnect all devices, including the KTB5's charging cord.
Verify the maximum power requirements for all devices, and confirm that the device power requirements do not exceed KTB5’s capacity (see GENERAL SPECIFICATIONS).
Reconnect
only
necessary devices.
Turn on USB ports and/or AC outlets and resume operation.
If an overload condition occurs on the input port, the portable battery will automatically shut off the input port. The port will be reactivated when the input source meets the
specification outlined in the GENERAL SPECIFICATIONS section. Only charge the unit with provided AC wall charger.
KLEIN TOOLS ACCESSORY MOUNT
13
To attach a Klein Tools accessory to KTB5, such as the AEPJS1 Wireless Jobsite Speaker, or 55437 Tradesman Pro
TM
Worklight, align the tabs on the accessory's mounting flange
with the slots on KTB5's Accessory Mount, then insert and rotate clockwise to lock into place. To remove the accessory, rotate counterclockwise and pull out.
ENGLISH