User guide

7
KEYPAD
N
O
P
Q
R
S
M
M
Up/Down
In Calibration Mode: the buttons are used to adjust the
measured cable length to match the known cable length
within the range of 25ft to 1000ft (10m to 300m).
In Tone Mode: the buttons select a cadence (HI, LO, HL1,
HL2).
N
Memory
The Memory button is used to store up to two NVP values
for testing purposes.
Short presses of the Memory button toggles between the
two memory storage locations: M1 and M2.
A long press (two seconds) of the button stores an NVP
value in the selected storage location.
O
+
A long press (two seconds) of the Memory and Calibration
buttons simultaneously toggles between units of
measurement (feet and meters).
P
Calibration
The Calibration button allows you to discover the NVP
value based on an inputted cable length.
Short presses of the Calibration button adjust cable
length in increments of 50ft or 20m within the range of
50ft to 1,000ft or 20m to 300m.
A long press (two seconds) of the Calibration button
aborts Calibration mode and enters Test Mode.
Q
Test
The Test button initiates length testing on the connected cable.
A short press runs a single test on demand.
A long press (two seconds) of the button starts loop
testing. Pressing any button (except Power) stops loop
testing (or the unit turns off after 3 minutes).
R
Tone
The Tone button allows you to trace cables by sound.
A short press of the button transmits an audio tone from
the unit through the connected cable.
Subsequent presses of the Tone button toggle between
Test and Tone modes.
An analog tone probe (not included) must be used in
order to hear the tone.
S
Power
A long press (two seconds) of the Power button powers
on the
Ranger™ TDR.
Subsequent presses of the button toggle the backlight on and off.
A long press (two seconds) of the button powers off the
Ranger™ TDR.