Service Manual

Whether the wiring
between the high pressure
switch and main control
board is connected well or
correctly
Whether the wiring
between the high pressure
switch and main control
board is connected well or
correctly
Method: Disconnect the plug.
Measure the resistance of the
high pressure protector, if
the protector is normal the
value is o,
Method: Disconnect the plug.
Measure the resistance of the
high pressure protector, if
the protector is normal the
value is o,
Yes
Connect it well
Connect it wellNo
Replace high pressure protector
Replace high pressure protectorNo
Whether the high
pressure protector
is broken
Whether the high
pressure protector
is broken
No
Stop the unit
Stop the unit Yes
Check if the outdoor unit
ventilation is good
Check if the outdoor unit
ventilation is good
Yes
Make the outdoor unit ventilate well
Make the outdoor unit ventilate well
Check whether the heat
exchanger is dirty
Check whether the heat
exchanger is dirty
No
Clean the heat exchanger
Clean the heat exchangerYes
Check whether the refrigerant
system is ok
Check whether the refrigerant
system is ok
Replace outdoor main
board
Replace outdoor main
board
No
High pressure protection
High pressure protection
Check if the outdoor fan runs
properly
Check if the outdoor fan runs
properly
please refer to the solution of fan
speed has been out of control
malfunction . Find out the cause and
have it solved.
please refer to the solution of fan
speed has been out of control
malfunction . Find out the cause and
have it solved.
No
Yes
NO
Yes
Check whether the outdoor
ambient temperature is
higher than 122ºF (50ºC)