failure, will restore those setting automatically within 3
minutes after power returns.
If the unit was in forced cooling mode, it will run in
this mode for 30 minutes and turn to auto mode with
temperature set to 76°F.
If there is a power failure while the unit is running, the
compressor starts 3 minutes after the unit restarts. If
the unit was already off before the power failure, the
compressor starts 1 minute after the unit restarts.
3.11 Refrigerant Leakage Detection
With this new technology, the display area will show “EC”
when the outdoor unit detects refrigerant leakage.
3.12 Ionizer/Plasma (for some models)
Press “Fresh” for at least 2 seconds on the remote control
to enable the IONIZER function. While this function is
active, the Ionizer/Plasma Dust Collector(depending on
models) is energized and will help to remove pollen and
impurities from the air.