Service Manual
Table Of Contents
Outdoor Unit Disassembly 34
4. PCB board 5
Procedure Illustration
1) Unfix the hooks and then open the
electronic control box cover (4
hooks)(see Fig. 4.1).
2) Disconnect the connector for fan
motor from the electronic control
board (see Fig. 4.2).
3) Remove the connector for the
compressor (see Fig. 4.2).
4) Pull out the two blue wires
connected with the four way valve
(see Fig. 4.2).
5) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor
ambient temp. sensor(T4) and
discharge temp. sensor(TP) (see Fig.
4.2).
6) Disconnect the electronic expansion
valve wire (see Fig Fig. 4.2).
7) Then remove the electronic control
board.
Fig. 4.1
Fig. 4.2
Note: This section is for reference only. Actual unit appearance may vary.
Reactor
DR
T3, T4, TP
Compressor
Electronic Expansion Valve
4-Way Valve