Installation Manual

13
Connect the cable between indoor
unit and outdoor unit
Before performing any electrical
work, turn off the main power to the system.
NOTE:
Terminal block of indoor unit
Electronic box
cover
Front Panel
Fig.27
Cover
Screw
Fig.26
ELECTRICAL WORK
To outdoor unit
Cord clamp
L1 L2 S
or
To outdoor unit
L N S
115V~60Hz
115V~60Hz
208-230V~60Hz
208-230V~60Hz
To indoor unit
To indoor unit
To power supply
To power supply
L1 L2 S L1 L2
Terminal block of outdoor unit
1(L) 2(N) S L N
G
G
G
G
G
G
1. The connection cables of indoor and outdoor
units have been connected to the terminals
on the control board except the grounding
wire(Y/G), only white plug connectors exposed.
See Fig.27.
2. Remove the control cover from the outdoor
unit by loosening the screw.
3. Hold the indoor male plug and insert it into the
female plug of the outdoor unit until it fixed with
a clicking sound. Secure the cable onto the
control board with the cord clamp. See Fig.27.
4. Connect the grounding wire to the terminal on the
control board individually.
5. The electrical connection has finished now.
L
N
S
S
L1
L2