SERIES OWNE'R MANUAL AIR CONDITIONER Thank you very much for purchasing our air conditioner, please read this owner's manual carefully before using your air conditioner.
CONTENT IMPORTANT SAFETY INFORMATION---------------------------------------------------------------------1 HINTS FOR ECONOMICAL OPERATION-----------------------------------------------------------------2 PARTS NAMES----------------------------------------------------------------------------------------------------2 MANUAL OPERATION-----------------------------------------------------------------------------------------14 ADJUSTING AIR FLOW DIRECTION-----------------------------------------------------------
IMPORTANT SAFETY INFORMATION Danger ! CAUTION Do not attempt to install this unit by yourself. This unit requires installation by qualified persons. ! DANGER Do not attempt to service the unit yourself. This unit has no user serviceable components. Opening or removing the cover will expose you to dangerous voltage. Tuning off the power supply will not prevent potential electric shock. ! DANGER Never put hands or objects into the Air Outlet of indoor or outdoor units.
Four-way Cassette(slim) Type 11 10 Control board 12 11 10 13 10 14 15 11 Indoor Unit Assy 1 12 6 5 Manual SET OPERATION TIMER DEF./FAN. ALARM OPERATION TIMER DEF./FAN. ALARM 9 4 8 14 13 15 12 13 14 15 NOTE: These three indication lamps flash in cycles when solar PV ECO function is activated.(Applicable to the unit adopts solar photovoltaic system only.
MANUAL OPERATION Ceiling & Floor This function is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. Two modes including AUTO and FORCED COOL can be selected through the TEMPORARY BUTTON on the air-in grill control box of the indoor unit. Once you push this button, the air conditioner will run in such order: AUTO, FORCED COOL, OFF, and back to AUTO. 1 AUTO The OPERATION lamp is lit, and the air conditioner will run under AUTO mode.
ADJUSTING AIR FLOW DIRECTION Cassette Type While the unit is in operation, you can adjust the air flow louver to change the flow direction and naturalize the room temperature evenly. Thus you can enjoy it more comfortably. 1. Set the desired air flow direction. Push the SWING button to adjust the louver to the desired position and push this button again to maintain the louver at this position. 2. Adjust the air flow direction automatically. Push the SWING button, the louver will swing automatically.
MAINTENANCE ! WARNING WARNING Before you clean the air conditioner, be sure to disconnect the power supply plug. Cleaning the indoor unit and remote controller ! CAUTIONS Use a dry cloth to wipe the indoor unit and remote controller. A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Never use a damp cloth on the remote controller.
Cassette Type 1. Open the air-in grill Push the grill switches towards the middle simultaneously as indicated in sketch A. Then pull down the air-in grill. Cautions: The control box cables ,which are originally connected with the main body electrical terminators must be pulled off before doing as indicated above. A B 2. Take out the air-in grill (together with the air filter shown in Sketch B) Pull the air-in grill down at 45 o and lift it up to take out the grill. 3. Dismantle the air filter 4.
4. Clean the air filter (Vacuum cleaner or pure water may be used to clean the air filter. If the dust accumulation is too heavy , please use soft brush and mild detergent to clean it and dry out in cool place) . Fig. 1 Fig. 2 The air-in side should face up when using vacuum cleaner. (See Fig. 1) The air-in side should face down when using water. (See Fig. 2) Cautions : Do not dry out the air filter under direct sunshine or with fire. 5. Re-install the air filter 6.
Special functions Refrigerant Leakage Detection(optional): With this new technology, the dipsplay area will appear EC (if applicable) and the LED indication lamps continue flashing when the outdoor unit detects refrigerant leakage. Louver Angle Memory Function(optional): For some models, the machine is special designed with louver angle memory function. Power failure during operation or pressing the ON/OFF button on the remote controller will stop the unit completely.
TROUBLES AND CAUSES Before you ask for servicing or repairs, check the following points. Recheck Inoperative The power fuse is blown or the circuit breaker has been tripped. The batteries in the remote controller are exhausted. The timer is set. Does not cool or heat well. The air inlet or outlet of the outdoor unit is blocked. Doors or windows are open. The air filter is clogged with dust. The louver is not at the correct position. The fan speed is set to low.
The Transmission Indicator " " Never Comes On Symptoms Reason and Disposal Causes The remote control signal is not transmitted even when the ON/OFF button is pushed. Check whether the batteries in the remote controller are exhausted. The remote control signal is not transmitted, because the power supply is off. The Display Never Comes On Symptoms Reason Causes Check whether the MODE indicated on the display is "FAN ONLY". FAN ONLY The TEMP. indicator does not come on.
The following displays indicate an error or problem: NO Malfunction Display (nixie tube) timer lamp running lamp (flashes per second) E0. OFF 1 Communication malfunction between indoor and outdoor units E1. OFF 2 3 Indoor fan speed malfunction E3. OFF 4 4 Indoor room temperature sensor open circuit or short circuit E4. OFF 5 5 Evaporator coil temperature sensor open circuit or short circuit E5. OFF 6 6 Refrigerant leakage detection malfunction EC.
The Klimaire logo is a registered Trademark of Klimaire Products inc. Copyright 2014 Klimaire Products Inc. 2190 NW 89 Place, Doral, FL 33172 - USA Tel: (305)593-8358 Fax (305) 675-2212 www.klimaire.com sales@klimaire.com The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.