Spec Sheet

Table Of Contents
KUIR - KFUF / KSIE - KSIR
Floor-Ceiling Unit Technical Specifications
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
H
D
W
H
D
W
H
D
W
KUIR18-H2 KUIR24-H2 KFUF036-H2G1 KFUF048-H2G1
KSIE018-H220-O KSIE024-H220-O KSIR036-H218 KSIR048-H218
V-ph-Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Capacity
Btu/h
18000 24000 36000 48000
Cooling EER
Btu/W
12,5 12,5 8,0 9,3
SEER 20 20 16 17,8
Capacity
Btu/h
18000 24000 38000 50000
Heating @ 47º F COP
W/W
3,2 3,8 2,8 3,2
HSPF 10,5 11 10,0 11,0
Heating @ 17º F Rated capacity
Btu/h
12000 15000 25400 35000
A
15 18 30 35
A
20 25 50 50
Indoor fan motor Input
W
100 100 130 96
RLA
A
1,5 2 1,5 1,8
Speed(Hi/Med/Lo)
rpm
950/850/750 1350/1260/1120 1300/1150/800 1320/1200/1120
Indoor air flow (Hi/Med/Lo)
cfm
578/521/465 759/708/598 1037/917/638 1350/1120/1000
Indoor noise level (Hi/Med/Lo)
dB(A)
47/44/39 53/48/42 54/49/43 57/54/52
Indoor unit Dimension (WxDxH)
in
42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25
Packing (WxDxH)
in
45.08x29.72x12.32 45.08x29.72x12.32 53.54x29.72x12.32 67.91x29.72x12.32
Net/Gross weight
lb
55.12/65.48 58.42/69.23 69/81.57 83.78/97
Design pressure
psig
550/340 550/340 550/340 550/340
Drainage water pipe diameter
in
1 1 1 1
Refrigerant piping Liquid side/Gas side
in
1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8"
Controller Remote control Remote control Remote control Remote control
Room temperature
Cooling
62~90
Heating
32~86
Operation temperature 62~86 62~86 62~86 62~86
Minimum circuit ampacity
Max. fuse size
Klimaire Indoor Unit Model Number
Klimaire Outdoor Unit Model Number
Power supply
ºF
ºF
ºF
62~90
32~86
62~90
32~86
62~90
32~86
SYSTEM
Product Series
E: Series
S: Universal Wall Mout
T: Ceiling Cassette
D: Slim Duct
U: Floor-ceiling
Nominal Caoacity
09 : 9,000 Btu/h
12 : 12,000 Btu/h
18 ; 18,000 Btu/h
24 ; 24,000 Btu/h
K
U
I
R
12
H
2
Power Supply
2 : 208-230 / 1 / 60
Operational Information
H: Heat Pump
Unit Type
I : Inverter
Model
Brand
K: Klimaire
INDOOR UNIT PRODUCT CODE
OUTDOOR UNIT PRODUCT CODE
K
S
I
E
018
H
2 24
Efficiency
SEER
Power Supply
1 : 115 / 1 / 60
2 : 208-230 / 1 / 60
Operational Information
H: Heat Pump
C: Cooling Only
Product Series
Unit Type
I : Inverter
Model
S: System
Brand
K: Klimaire
18: 18,000 Btu/h
24: 24,000 Btu/h
36: 36,000 Btu/h
48: 48,000 Btu/h
O
Nominal Capacity
Unit Type
O: Outdoor
Production
XX
E: Series
R: Series
Production
XX

Summary of content (1 pages)