User's Manual

Table Of Contents
User Manual for POD Systems Revision: 0.7
© KMW USA Inc.
1818 E. Orangethrope Ave, Fullerton, CA 92831
Tel. +1 (714) 515-1100
www.kmwcomm.com
20
Table 1-1 POD System Scalability & Limitations
Supported maximum number
# of path/Module
POD System
1)
/Rack
/H-SRU
H-DMCU
1
RACK
4
H-PSU
4
1
2)
H-SRU
26
7
H-FEM
H-FEM-L
208
84
3)
12
4)
2
9)
H-FEM-H
1
H-COM-8
26
26
12
4)
H-DTM 8x8
26
26
6
4)
HOM
32
28
4
5)
RU
256
6)
224
7)
32
8)
H-OIM-B
4
4
4
H-OEM-S
6
6
6
1) Table 1-1 shows hardware capacity of one POD system.
2) One H-PSU supports one rack with 7 H-SRU which is fully filled with modules.
3) The number of supported H-FEM/rack = 7 H-SRU x 12 H-FEM/H-SRU = 84
4) One H-SRU consists of 12 slots. So, it supports up to 12 modules with 1 slot size (H-FEM & H-COM-8) and 6
modules with 2 slot size (H-DTM 8x8).
5) The number of supported HOM/H-SRU is limited up to four (4).
6) The number of supported RU in POD system is limited up to 256.
7) The number of supported RU/rack = 7 SRU/rack x the number of supported RU/SRU = 224
8) The number of supported RU/H-SRU = 4 HOM/SRU x 4 path/HOM x 2 RU/path = 32
9) H-FEM-L-P (PCS) supports only one path.