User's Manual

Table Of Contents
User Manual for POD Systems Revision: 0.7
© KMW USA Inc.
1818 E. Orangethrope Ave, Fullerton, CA 92831
Tel. +1 (714) 515-1100
www.kmwcomm.com
55
Figure 2-49 AC input on/off Switch & DC output on/off switch
AC input on/off switch
- Be able to turn AC input on (off) manually by using AC input on/off switch
DC output on/off switch
- Be able to turn each DC output on (off) separately
- Toggle type
When you press DC output on/off switch, the LED light of DC output on/off switch and 24V DC output
turn on, and when you press it again, LED light and 24V DC output turn off.
- DC output on/off switch can be turned on (off) in local and remote site
2.1.12.6 AC input port & DC output port
Figure 2-50 AC input port & DC output port
AC input port
- Use 3 wire AC code (Line, Neutral, GND)
DC output port
- One DC output port for H-DMCU
DC output connector contains +24V DC, Rack ID, and insert pin.
- Eight DC output port for H-SRU
Each DC output connector contains +24V DC, Rack ID, and insert pin.
2.1.12.7 Rack ID
Figure 2-51 Rack ID
Group is not used
Rack ID
- Rack ID can be set from 1 to 4.
- One H-DMCU can support up to 4 racks, and one H-DMCU needs maximum 4 H-PSU because one H-PSU can
supply 24V DC power to only one rack that can be composed of up to 8 H-SRUs and one DMCU.
- H-DMCU and each H-SCM in H-SRU can identify its own rack ID through the cable connection with H-PSU.
HPSU
#1 #2 #3 #4
#5 #6 #7 #8
#1 #2 #3 #4 #5 #6 #7 #8
DMCU HSRU
#1 #2 #3 #4
1 2 1 2
Group Rack