User's Manual

Table Of Contents
User Manual for POD Systems Revision: 0.7
© KMW USA Inc.
1818 E. Orangethrope Ave, Fullerton, CA 92831
Tel. +1 (714) 515-1100
www.kmwcomm.com
40
LED
Table 2-15 POD-H-FEM-H-x LED Operation
Specifications
PWR
Solid Green
When power is on.
Off
When power is off.
ALM
Off
When H-FEM-H-x has no alarms.
Solid Yellow
When H-FEM-H-x has minor alarm.
Solid Red
When H-FEM-H-x has major alarm.
DL Out
Blink Green
At the cable connection guide, green led blinks to indicate which
RF ports should be connected to.
UL In
Blink Green
T-sync #1~#4
Blink Green
2.1.6.4 Communication port
Figure 2-26 Communication Port
- This port provides communication path between H-FEM-H-x and H-SCM through backboard of H-SRU.
- +24V DC is provided through this communication port from backboard of H-SRU.
- H-FEM-H-x acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication
port. The IP address of H-FEM-H-x is assigned automatically using the acquired ID information.
2.1.6.5 Alarms
Table 2-16 POD-H-FEM-H-x - Alarms
Alarm Name
Description
Remedy
Alarm
Severity
LED
color
High Temperature
Temperature too high
Check environment
Major
Red
Temperature high
Minor
Yellow
Low Temperature
Temperature too low
Minor
Yellow
Downlink High Input
Power
RF signal too high
Check H-FEM downlink input level/
attenuator configuration/ALC status
Major
Red
RF signal high
Major
Yellow
Uplink High Output
Power
RF signal too high
Check H-FEM uplink input level/ attenuator
configuration/ALC status
Major
Red
RF signal high
Major
Yellow
Downlink Low Input
Power
RF signal too low
Check H-FEM downlink input level/
attenuator configuration/RF cabling
Minor
Yellow
Link
Communication fail
Check pin of communication port/ assigned
IP address
Major
Yellow
Freeze
The final stage of
Shutdown process
Check if shutdown process is going again
after reset
Major
Red
Downlink ALC
Activation
ALC activation
Check H-FEM downlink input level/
attenuator configuration
Warning
Yellow
Sync fail
(H-FEM-L-B only)
No TDD sync signal is
acquired
Check H-FEM downlink signal input received
from BTS
Major
Yellow