42
Connected to UL input port of H-FEM
Connector Type: SMB-L Female
LED
Table 2-17 POD-H-COM-8 LED Operation
Specifications
PWR
Solid Green
When power is on.
Off
When power is off.
ALM
Off
When POD-H-COM-8 has no alarms.
Solid Yellow
When POD-H-COM-8 has minor alarm.
Solid Red
When POD-H-COM-8 has major alarm.
DL #1 ~ #8
Blink Green
At the cable connection guide, green led blinks to indicate which
RF ports should be connected to.
DL COM
Blink Green
UL #1 ~ #8
Blink Green
UL COM
Blink Green
2.1.7.4 Communication port
Figure 2-29 Communication Port
- This port provides communication path between H-COM-8 and H-SCM through backboard of H-SRU.
- +24V DC is provided through this communication port from backboard of H-SRU.
- H-COM-8 acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port.
The IP address of H-COM-8 is assigned automatically using the acquired ID information.
2.1.7.5 Alarms
Table 2-18 POD-H-COM-8 - Alarms
Alarm Name
Description
Remedy
Alarm
Severity
LED
color
High Temperature
Temperature too high
Check environment
Major
Red
Temperature high
Minor
Yellow
Low Temperature
Temperature too low
Minor
Yellow
Link
Communication fail
Check pin of communication port/
assigned IP address
Major
Yellow
Downlink ALC
Activation
ALC activation
Check H-COM-8 downlink input level/
attenuator configuration
Warning
Yellow