User's Manual

Table Of Contents
User Manual for POD Systems Revision: 0.7
© KMW USA Inc.
1818 E. Orangethrope Ave, Fullerton, CA 92831
Tel. +1 (714) 515-1100
www.kmwcomm.com
56
- CAUTION) The rack ID connected to H-DMCU must be set as 1.
Table 2-28 Rack ID
DIP Switch Setting
Group 1
Group 2
Rack 1
Rack 2
Rack ID #1
X
X
OFF
OFF
Rack ID #2
X
X
ON
OFF
Rack ID #3
X
X
OFF
ON
Rack ID #4
X
X
ON
ON
2.1.12.8 Ground port
- Refer to section 3.2.2
2.1.12.9 Alarms
Table 2-29 POD-H-PSU - Alarms
Alarm Name
Description
Remedy
Alarm
Severity
LED
color
High Temperature
Temperature too high
Check environment
Major
Red
Temperature high
Minor
Yellow
Low Temperature
Temperature too low
Minor
Yellow
Voltage
High Voltage
Check if High voltage alarm occurs again
after reset.
Major
Red
Current
High Current
Check if current alarm occurs again after
reset.
Major
Red
Low Voltage
Low Voltage
Check if low voltage alarm occurs again
after reset.
Major
Yellow