4.2.1.3 AC or DC power cable connection
- After taking out of gasket from power cable entrance located in right side, pass power cable through this
entrance.
- Connect power cable to AC (or DC) power terminal. In case of AC power cable, fasten ground cable by using
GND SCREW to GND position located on the right top side in debug window.
- Replace gasket into power cable entrance.
- If there is no expansion RU connected main RU, close/fasten the door for debug window and front door by
using SECURITY SCREWS (M4) and allowed Torque: 12.0 Kgfcm.
- If there is an expansion RU connected main RU, continue in section 4.2.1.4.