Advanced Power Conditioners Installation Instructions

PRM150 and PRM200 SPECIFICATIONS
Current rating: PRM150 15 amps (1800 watts at 60/120 VAC,
60 HZ) fuse protected.
PRM200 20 amps (2400 watts at 60/120 VAC,
60 HZ) fuse protected.
Voltage Ranges: 90-135 VAC 60 Hz
Remote trigger voltage: 3-24 VDC (input impedance 1k ohm)
Clamping Voltage 250v peak (175 volts RMS)
Response time: 1 nanosecond
Max Surge Current: 72,300 amps
Max Spike Energy: 2210 joules (AC line)
740 joules (cable and sat dish)
640 joules (telephone line)
3590 joules total protection
Noise attenuation: >25 dB at 200 kHz
>60 dB at 5 mHz
RF pass thru loss Less than 1 dB below 800 mHz
Outlets: Eight rear
Power consumption: Five watts maximum
Dimensions: 1.75”H x 17” W x 11”D
Weight 8 lbs (3.6 kg).
Construction: Steel chassis, powder coated; glass epoxy
printed circuit boards
Power Consumption: 8.5 watts for display and control circuits,
Warranty
Knöll Systems warrants its products sold in the USA and Canada by authorized Knöll dealers to be free of defects in
materials and workmanship. This warranty extends for three full years from the date of purchase by the original
consumer. Any products returned to Knöll Systems and found to be defective by Knöll Systems within the warranty
period will be repaired or replaced at Knöll Systems option, at no charge. Knöll Systems will not be responsible for the
actual cost of installation or removal of the product, nor for any incidental or consequential damages. Some states do
not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to
you. This warranty gives you specific legal rights. You may have additional legal rights that vary from state to state.
Knoll Systems
145 Tyee Drive Point Roberts, WA 98281
11791 Machrina Way, #120 Richmond BC V7A 4V3
tel (604) 272 4555, fax (604) 272 5595
www.knollsystems.com
Made in Canada
PRM150 2002-2003 Knoll Systems All Rights Reserved