TROUBLESHOOTING CHART
Note: Troubleshooting problems may have similar causes and solutions.
I
PROBLEM
Low pressure or not
enough air
or
Compressor does not
stop
Excessive starting and
stopping, while not in use
POSSIBLE CAUSE
Tank petcock is open
Prolonged excessive use of air
Compressor not large enough
Restricted check valve
Hole in air hose
Tank leaks
Blown seals
Valve leaks
Fittings leak
Air leaks from regulator, Dirty or damaged regulator
or regulator does not internal parts.
regulate pressure
Regulated pressure This is normal If pressure drops too low, adjust regulator while accessory is used.
reading drops when air Compressor not large enough Check air requirement of accessory. If it is higher than CFM and
accessory is being used )ressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.
Circuit breaker trips (fuse Low voltage Furnish adequate power. If using extension cord, try without.
blows) too often Excessive wire length Consult electrician.
Restricted air passages Contact authorized service center.
Overheating Poor ventilation Relocate compressor to an area with cool, dry and well-circulated
air.
Clean all cooling surfaces of pump and motor thoroughly.
Replace worn parts and reassemble with new seals.
Motor stalls Furnish adequate power.
Pressure relief valve Contact authorized service center.
opens
Motor will not run
Dirty cooling surfaces
Leaking valve
Low voltage
Tank pressure exceeded normal
operating pressure
Control board failure
Tank pressure exceeds preset
_ressure switch limit
Motor overload protection has
tripped
Fuse blown or circuit breaker
tripped
SOLUTION
Close petcock
Decrease amount of air used.
Check air requirement of accessory. If it is higher than CFM and
)ressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.
Remove and clean or replace.
Check and replace if necessary.
_k LvAvg-'1=_l_ll_[=']mlmmediately replace tank. DO NOT attempt to repair.
Replace any faulty seals.
Replace worn parts and reassemble with new seals.
Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.
Replace worn parts and reassemble with new seals.
Replace any faulty seals.
Replace regulator or internal parts.
Contact authorized service center.
Motor will start automatically when tank pressure drops below
kick-in pressure of pressure tank.
Let motor cool off and overload switch will automatically reset. This
may take several minutes.
Replace blown fuse or reset circuit breaker. Do not use fuse or
circuit breaker with higher rating than specified for your branch
circuit.
Check for proper fuse; "Fusetron" type T is acceptable.
Check for low voltage and proper extension cord size.
Disconnect other applications from circuit. Operate compressor
on a dedicated circuit.
Remove and clean or replace.
Check for proper gauge and extension cord length.
Check valve stuck open
Wrong wire gauge in extension
cord
Loose electrical connections Contact authorized service center,
Paint spray on internal motor Have checked at service center. Do not operate compressor in the
_arts paint spray area
Possible defective motor Have checked at service center.