MSDS
Material Safety Data Sheet
Report No.: STR11058231S Page 6 of 10
SEM.Test Compliance Service Co., Ltd.
3/F,Jinbao Commerce Building, Xin'an Fanshen Road,
Bao'an District, Shenzhen, P.R.C
Collect all contaminated absorbent and dispose
of according to directions in Section 13. Scrub
the area with detergent and water; collect all
contaminated wash water for proper disposal.
Section 7 – Handling and Storage
Handling Don’t handling Li-ion Battery Pack with
metalwork. Do not open, dissemble, crush or
burn battery. Ensure good ventilation/
exhaustion at the workplace.
Prevent formation of dust.
Information about protection against explosions
and fires: Keep ignition sources away- Do not
smoke.
Storage If the Li-ion Battery Pack are subject to storage
for such a long term as more than 3 months, it is
recommended to recharge the Li-ion Battery
Packperiodically.
3 months: -10℃~+40℃, 45 to 85%RH
And recommended at 0℃~+35℃ for long period
storage.
The capacity recovery rate in the delivery state
(50% capacity of fully charged) after storage is
assumed to be 80% or more.
The
voltage
for
a
long
time
storage
shall
be
3.7V~4.2V range.
Do not storage Li-ion Battery Pack haphazardly
in a box or drawer where they may short-circuit
each other or be short-circuited by other metal
objects.
Keep out of reach of children.
Do not expose Li-ion Battery Pack to heat or fire.
Avoid storage in direct sunlight.
Do not store together with oxidizing and acidic
materials.
Section 8 – Exposure Controls and Personal Protection
Engineering Controls Use local exhaust ventilation or other
engineering controls to control sources of dust,
mist, fumes and vapor.
Keep away from heat and open flame. Store in a
cool, dry place.
Personal Protective Equipment
Respiratory Protection: Not necessary under
SEM.Test Compliance Service Co., Ltd