User Manual

64
(f) ALL PPI/PPI Screen
Note1: The RANGE, RINGS interval, and Display mode are shown on
top of the screen.
Note2: When you press any key except "MENU", "RANGE
UP/DOWN", "BRILL", and "POWER", the screen will return
to PPI/PPI mode.
Note3: Each radar picture is updated every two antenna scans. The
right screen picture is frozen while the left screen is updated, and
vice versa. When your ship navigates at high speed, use a single
PPI screen to obtain faster picture update.
(g) MOB Screen
The MOB key has been pressed, the MOB position and ship's
position are displayed. If not, MOB position will be displayed with
bars( --.- )
Press MOB key to clear the MOB position and return to previous
screen. Press ENT key to return previous screen with keeping the MOB
position data.
5.5.4.2 Switching screens on PPI/PPI screen ( SEL WIN )
Switching to the desired screen for activation on a PPI/PPI screen display.
The "SEL WIN" function switches the activated screen to effect the operation such as, RANGE, GAIN,
STC, FTC, VRM1/2, EBL1/2, and guard zone. The range indicator of activated screen is displayed in reverse.
When "SEL WIN" is selected with the up-down cursor keys from among the pull- down display items
and the "ENT" key is pressed, activated screen will be changed to the opposite screen.
Up/Down ENT the opposite screen activated
(select SEL WIN)
+
ALL PPI PPI screen
.75
.25 HU S
6
1
MAN OVERBOARD
MOB POS
37
°
08. 42N
142
°
03. 33E
SHIP’S POS
37
°
12. 42N
142
°
04. 33E
PRESS MOB KEY TO DATA CLEAR
PRESS ENTER KEY TO RETURN
Range display on the active screen become a reverse display
.75
.25 S
.5
.25
.75 .25 HU S
.5 .25 .