User Manual
51
5.5.1.9 Establishment of the indication of the RANGE RINGS (RINGS) 
(1) Press the up-down cursor key to select RINGS from the pull-down menu, and then press the “ENT” key. 
(The ON/OFF sign will appear beside the letters RINGS) 
(2) Use the up-down key to select ON or OFF and press the “ENT” key 
Select ON  Range Rings ON 
Select OFF   Range rings OFF 
Up/Down  →  ENT   →  Up/Down (Select ON)  →  ENT -------------Range rings appear. 
(Select RINGS) 
→
  Up/Down (Select OFF) →  ENT ---------Range rings disappear. 
<Number of range rings and range interval> 
RA53
Range  0.125
 0.25  0.5  0.75
1.5  3  6  12  24  48  64
Number of Rings  2  2  2  3  6  6  6  6  6  6  4
Interval  0.0625
0.125  0.25
0.25
0.25
0.5  1  2  4  8  16
RA54
Range  0.125
 0.25  0.5  0.75
1.5  3  6  12  24  48  72
Number of Rings  2  2  2  3  6  6  6  6  6  6  6
Interval  0.0625
0.125  0.25
0.25
0.25
0.5  1  2  4  8  12
5.5.1.10 Variable range function ( VAR RNG ) 
The range scales are allocated as 0.5--0.75--1.5--3.0--.....as standard. However, using this function, a 
consecutive range scaling is also available such as 0.5--0.6--0.7--0.8--..... . 
(1) Use the up-down cursor keys to select VAR RNG from the pull down menu and press the "ENT" key. 
(2) When you select ON with the up-down cursor key from the ON/OFF display beside the VAR RNG item, 
and then you press the "ENT" key, the VAR RNG function becomes valid and  VAR  will be displayed 
in the upper left corner of the screen (beside MODE). 
 Setting procedure 
Up/Down  →  ENT   →  Up/Down (Select ON)   →  ENT   VAR RNG function is 
         turned ON. 
 (Select VAR RNG) 
→ 
Up/Down (Select OFF)  →  ENT   VAR RNG function is 
           turned OFF. 
(3) The range changes continuously by pressing the up or down cursor key while the VAR RNG function is 
on, and it changes in step with the "RANGE UP" or "RANGE DOWN" key. 
 Method of use 
Up/Down -------------------------------------Range changes continuously 
RANGE UP & RANGE DOWN ---------Range changes in step 
(4) To cancel the vari-range function, press any key except the "RANGE UP" and "RANGE DOWN" keys.  
.75
.25 
HU 
.75
.25 
HU 
Range rings ON 
Range rings OFF 