Tab.3-1 Optional Interconnecting Cable
In addition to the above components included with your package, the following items are also re-
quired. Please prepare them separately.
Item QTY Remarks
Tapping screw or M5 bolt and nut 6 sets To install display unit
Grounding wire 1 Earth line for display unit
Grounding wire and crimp terminal 1 set Earth line for scanner unit
3.2 Checking Power Supply Voltage
3.2.1 Power Supply Requirements
For the RA53/54 radar to be operated normally, the power supply (battery) detailed in Tab.3-2 is
required. Note also that if the battery is discharged, its voltage may fluctuate greatly, causing the radar
to malfunction. When to starting up the radar system or starting transmitting, an additional rush cur-
rent is required on the power supply line. Carefully check the power supply system including wiring by
using a circuit tester.
Tab.3-2 Power Supply Requirements
*A.C. power cannot be used
3.2.2 Fuse Replacement
For the RA53/54 radar to be operated safely, proper rated fuses must always be used. Tab.3.3 is
fuse rating table. All these fuses are provided as spares.
Tab.3-3 Supply Voltage vs Fuse Ratings
RA53/RA54
Cable length Product No.
15m 242J159098B
20m 242J159098C
30m 242J159098D
Supply voltage used
Maximum current
Allowable range of voltage
DC12V 14A 10.2-41.6V
DC24V 6A 10.2-41.6V
Main Fuse Motor Fuse
15A/250V or 125V *
(6.3 dia. x 32mm)
T3.15A/250V or 125V
(5 dia. x 20mm)