User Manual
22
3.6 Installing Display Unit
After you have finished installing the scanner unit, install the display unit in the same way. Choose
the proper bolt length according to the thickness of the surface on which you are going to install the
display unit. Hole diameter is different using bolts from using tapping screw. When using tapping screw,
open holes in adequate holes. When using bolts and nuts, open holes in diameter of 6 mm (0.24 in.). When
you have opened holes, install the pedestal part first and then the display unit.
Fig.3-6 Hole positions for display unit
Note : When you install the display by flush mount, refer to appendix "OUTLINE DRAWING".
Slide off four triangle corner covers, and fix the display unit to the panel with screws. After fixing the
display unit, put on corner covers to the corner of the display unit. See APPENDIX.
3.7 Connecting Cables
Lay cables firmly in place by following the instructions below.
Note1: Do not bind the cable for the radar collectively with cables of other equipment (espe-
cially power supply cable).
Note2: Leave clearance near the inlet of the display so you can remove the display unit eas-
ily. This facilitates installation and maintenance of the display unit. (Refer to Ap-
pendix.)
Note3: Because the cable has a connector fitted on the display and scanner side, if it is nec-
essary to pass cable through a narrow path, fix the scanner-side connector vertically
using vinyl tape before passing cable through the path.
Note4: Lay cable along the ship's hull or wall surface and attach it in place at intervals of
about 40 cm.
3.7.1 Interconnecting cable (See Fig.3-9)
• Ensure that the radar is off. Connect the cable to the socket labeled "SCANNER" on the rear panel
of the display unit.
‚ Use a T-wrench to remove the back covers of scanner unit.
Avoid operating display in direct sunlight.
The temperature inside becomes high and
display may be broken.
!
WARNING
360
84
Fitting hole
(14.17 in.)
(3.31 in.)
Hole diameter
6mm : Bolts and Nuts
Adequate : Tapping screws
Recommended screw
M5 or equivalent
Unit : mm
47
(1.85 in.)
37
(1.46 in.)
60
(2.36 in.)
240
(9.45 in.)
60
(2.36 in.)
Forward