User's Manual

MDC-7000P/7900P Series Chapter 4 Target (AIS,TT and Trial manoeuvre)
0093169006-05E 4-21
By without using menu
1 Move cursor using trackball to the stationary target to be acquired, then press ACQ key.
2 Move cursor to the acquired target, then press ENT key.
Acquired target information will be displayed in “TGT INFO” area at side of the display.
3 Move cursor to the REF OFF positon in “TGT INFO” area at side of the display, and [OFF]
characters change to reverse characters.
Press ENT key to set REF target from TT target.
[GYRO] characters in the own ship information area at right side of the display change to yellow.
Move cursor using trackball to the [GYRO] characters, then press ENT key. [GYRO] characters
change to [REF] characters.
COG/SOG computed by the reference target can be used.