User's Manual
Chapter 4 Target (AIS, TT and Trial manoeuvre) MDC-7000P/7900P Series
0093169006-05E 4-28
Function check
This function is used to confirm the operation of Echo alarm, Manual acquisition TT (ARPA), Auto
acquisition, Past position and Guard zone.
Preparation
1 Set up the range to 12 NM.
2 Turn GAIN, RAIN and SEA knobs and set these levels at a minimum.
3 Set up the echo alarm as follows:
Press MENU key to display “Menu”.
Select [ALARM] => [ECHO ALARM] => [IN], and press ENT key.
Set up the echo alarm range.
4 Set up the Guard zone.
Select [ALARM] => [GUARD ZONE] => [EDIT] => [ON], and press ENT key.
Set up the range of Guard zone.
5 Set up the Auto acquisition.
Select [TARGET] => [AUTO ACQ AREA] => [ON], and press ENT key.
Set up the range of Auto acquisition.
AUTO ACQ AREA (TT, AIS)GUARD ZONE
ECHO
A
LARM
12NM