User's Manual
MDC-7000P/7900P Series Chapter 4 Target (AIS,TT and Trial manoeuvre)
0093169006-05E 4-35
In addition, the movement of the own ship and the other ships is displayed in vector after elapse of
the time set at [DELAY] of TRIAL MANOEUVRE setting menu.
3 TRIAL MANOEUVRE setting menu
Each numerical value in the grey background color area is set by user. Move the cursor to the grey
area, press ENT key, and a numerical value input dialogue box will appear. The value of the dialog
box can be set by the trackball.
For [TRIAL OFF], moved the cursor OFF and press ENT key, TRIAL MANOEUVRE is finished
immediately.
TRIAL: OFF
When the trial manoeuvre commences, count down starts from 300 seconds and ends at 0
second. When you decide to stop the function during the countdown, select the countdown
display and set OFF.
CRS T: This indicates own ship’s course after [DELAY].
SPD: This indicates own ship’s speed after [DELAY].
DELAY: This indicates the starting time of TRIAL MANOEUVRE. After the time set, the own ship
starts moving at [CRS T], [SPD], [RATE OF TURN], [RATE OF SPD].
RATE OF TURN: This indicates own ship’s rate of turn after [DELAY].
RATE OF SPD: This indicates own ship’s acceleration rate after [DELAY].
DELAY
T
TRIAL MANOEUVRE
TRIAL
CRS T
SPD
DELAY
RATE OF TURN
RATE OF SPD