User's Manual
MDC-7000P/7900P Series Chapter 7 System and Maintenance menu operation
0093169006-05E 7-5
7.6 MAINTENANCE MENU
STARTUP: Refer to 4.2 STARTUP menu of Installation manual.
I/O: Refer to 4.3 Setup I/O Interface of Installation manual.
SECTOR MUTE: Refer to 4.4 Setup SECTOR MUTE mode of Installation manual.
PRESET: Refer to 4.5 Setup PRESET of Installation manual.
BACKUP:
BITE: Refer to Chapter 9 Simple fault diagnosis.
TOTAL HOUR:
TX HOUR:
MENU SETUP:
PASSWORD: Refer to 1.3 Menu usage.
MON: Refer to 2.33 Performance monitor.
VERSION:
7.7 BACKUP of Setup data (Cannot be used while transmitting)
By saving setup data to the internal memory or external memory, the initial setup and all settings are
saved, in the event that the radar needs to be reinitialized or some setup changes been made, user can
go back to the original settings by restoring from memory.
Backup of setup data should be saved after initial setup.
In case of malfunction of display where re-initialization must be done, restore of backup data completed
at the time of original setup will bring all proper settings and tuning setup back to normal operation.
Internal save of setup data
Note: This menu is protected in normal. To cancel the protection, refer to 1.3 Menu usage “Display
[MAINTENANCE] menu”.
To save data internally at the time of setup,
1 Press MENU key to display “Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP SAVE] => [GO], and press ENT key.
To restore from internally backup after re-initialization,
1 Press MENU key to display “Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP LOAD] => [GO], and press ENT key.