User's Manual

MDC-7000P/7900P Series Chapter 9 Simple fault diagnosis
0093169006-05E 9-13
A A 17000 9 50 Trigger abnormal. Trigger from Scanner unit is not received.
A A 17000 10 51 Radar video abnormal. IF video from Scanner unit is not received.
A A 18000 1 13 Panel not connected. No communication between operating
panel is available. Connector (J9) is
disconnected.
B W 18001 1 37 Flash memory erase &
write error.
Flash memory erase and write error.
B W 18001 2 38 Flash memory erase error. Flash memory erase error.
B W 18001 3 39 Flash memory write error. Flash memory write error.
B W 18001 4 40 Flash memory checksum
error.
Flash memory checksum error.
B C 18002 1 71 SD card problem. SD card may be broken.
B C 18002 2 72 SD card not ready. There is not SD card.
B C 18002 3 73 SD card write protected. SD card is protect mode.
B C 18002 4 74 SD card not enough free
space.
Memory of SD card is not left.
B C 18002 5 75 Illegal data. The data does not agree.
B C 18002 6 76 USB memory problem. USB memory problem.
B C 18002 7 77 USB memory not ready. USB memory not ready.
B C 18002 8 78 USB memory write
protected
USB memory write protected
B C 18002 9 79 USB memory not enough
free space.
USB memory not enough free space.
B A 18003 1 JB-35 not connected. No communication between junction box
JB-35 is available. Connector J3 is
disconnected.
B A 18003 2 JB-35 not extended mode. There is not JB-35 with the extended
mode.