User's Manual
MDC-7000P/7900P Series For Your Safe Operation
0093169006-05E v
Caution rellated to Handling
ENGLISH
Caution related to rotating aerial
The radar antenna may start rotating to rotate without notice. Please stand
clear from the antenna for your safety.
Caution related to electromagnetic disturbance
The operating Antenna & Scanner unit radiates high-energy
electromagnetic wave. It may cause harmful effect for human body due to
its continuous radiation. As International regulation says, electromagnetic
waves less than 100 watt/m
2
does not have a harmful effect on human
bodies, but some kind of medical devices such as heart pacemakers are
sensitive even under the low energy electromagnetic wave. Any personnel
with such a device should keep away from the electromagnetic wave
generating position at all times.
Specified power density and distance from the radar (in accordance with the
provision as specified in IEC 60945)
Model name Transmission power /
Antenna length
100W/m
2
50W/m
2
10W/m
2
MDC-7012P
MDC-7912P
12kW / 4 feet Antenna 2.01m 2.84m 6.34m
12kW / 6 feet Antenna 2.38m 3.37m 7.54m
12kW / 9 feet Antenna 2.83m 4.01m 8.96m
MDC-7025P
MDC-7925P
25kW / 4 feet Antenna 2.89m 4.09m 9.15m
25kW / 6 feet Antenna 3.44m 4.86m 10.88m
25kW / 9 feet Antenna 4.09m 5.78m 12.93m