User's Manual

Chapter 9 Simple fault diagnosis MDC-5200/5500 Series
0093155002-03 9-6
9.5 Need to confirm serial input
This procedure is applied to confirm serial input of Display unit.
Serial input of connectors can be confirmed with the following 6 connectors:
AIS (J2), NMEA (J3, J5 and J6), Option1 (OP1) and Option2 (OP2).
OP1 and OP2 port will be effective when JB-35 is connected to J3.
1 Press MENU key to display “Menu”.
Select [MAINTENANCE] => [I/O] => [SERIAL MONITOR] => select [J3], [J5], [J6], [OP1], [OP2],
[AIS] or [ALL], and press ENT key.
OP1 and OP2 port will be effective when JB-35 is connected to J3.
[ALL] can confirm the data of all ports at a time.
2 Input data will be displayed.
Since the data keeps coming in and the display keeps changing it may be hard to observe the
sentences.
By pressing ENT key, data display will stop temporarily to confirm data content.
3 Move trackball/joystick to left to complete.
Data confirming item in step 2
In the case that data is not displayed: Confirm input data device connected to Display unit.
In the case that data is displayed but is garbled: Confirm baud rate.