User's Manual

MDC-5200/5500 Series Chapter 10 Specifications
0093155002-03 10-3
10.2 Display and Operation unit
*Requires heading data input.
**Requires heading and latitude/longitude data input.
***Requires heading, speed and latitude/longitude data input.
Model name MDC-5204/5206/5212/5225 MDC-5504/5506/5512/5525
Display unit MRD-111 MRD-109
Operation unit --- MRO-108
Display size and type 12.1 inch color LCD 15 inch color LCD
Resolution 768 X 1024 pixels (XGA)
Effective diameter 184 mm 228 mm
Viewing distance 1 m
Frequency band X-band 9410MHz ± 30MHz (9380MHz to 9440MHz)
Speed class Normal speed class (< 30 knot)
Echo color White, Yellow, Green, Multi, User1, User2
Off centering Max. 75%
Range data accuracy 8 m or 1 % of range scale selected, whichever is greater
Range 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48, 64, 96 NM
Up to 48 NM for transmit output 4kW,
Up to 64 NM for transmit output 6kW, 12 kW,
Up to 96 NM for transmit output 25kW
Bearing accuracy ±1°
Presentation modes Head up, North up*, and Course up*
Functions CFAR (Clutter rejection), Interference rejection, Expansion, Process
(Residual image, Averaging), VRM, EBL, Parallel index, ERBL, Cursor
position (Lat/Lon)**, Bearing (true/relative)*, Trail (true/relative)***, Own
ship past track, MAP (Event mark, etc.)**, RGB Monitor output, VDR output,
Inter-switch, C-map chart**
NMEA Input/output 3 CH (5 CH with JB-35)
Power supply 21.6 VDC to 41.6 VDC
MDC-5204: 100 W or less MDC-5504: 100 W or less
MDC-5206: 130 W or less MDC-5506: 130 W or less
MDC-5212: 150 W or less MDC-5512: 150 W or less
MDC-5225: 200 W or less MDC-5525: 200 W or less
AIS
1000 targets
TT (ARPA) 100 targets
Temperature -15°C to +55°C
Water protection IPX5 (Operation unit (MDC-5500 series): IP23)