Dimensions Guide
20-1/4"
Notes
Required Electrical Service
Measure your actual product for rough-in details.
One circuit required, protected with Class A Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
Install this product according to the installation
instructions.
120 V, 15 A, 50/60 HzAmplifier:
The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.
Technical Information
All product dimensions are nominal.
3-Wall AlcoveInstallation:
Provide one grounded electrical outlet within 24"
(610 mm) of each component.
LeftDrain location:
45-1/8" x 19-11/16" (1146 mm x 500 mm)Basin area, bottom:
Control amplifier fits 16" (406 mm) center studs.
25' (7.6 m) cables are included.
52-3/4" x 25-5/16" (1340 mm x 643 mm)Basin area, top:
91 lbs (41.3 kg)Weight:
ADA compliant when installed to the specific
requirements of these regulations.
45 lbs/ft² (219.7 kg/m²)Minimum floor load:
15" (381 mm)Water depth:
58 gal (219.6 L)Water capacity:
Amplifier: 120 V, 1.1 A, 50/60 HzElectrical component
rating:
2 at 15 W per channel
2 at 30 W per channel
Amplifier channels:
2-3/16" (56 mm)Minimum flat for door:
USA/Canada: 1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
12-3-2017 01:42
Archer
®
5' VibrAcoustic
®
Bath
K-1122-VBLA