Installation Guide
Operating Instructions (cont.)
NOTE: Refer to the Homeowners Guide included with your remote control for detailed operating
instructions.
The waterproof remote control is designed to be used in the bath and will float in the water.
The remote control uses two AAA batteries.
Flush the System
NOTE: Flush your whirlpool system twice a month or more, depending upon usage.
Turn the jet trim rings fully clockwise to reduce air induction.
Fill the whirlpool with hot water to a level at least 2″ (51 mm) above the highest jet.
Add 2 teaspoons (10 ml) of a low-foaming, powder automatic dishwasher detergent and 20 ounces
(590 ml) of household bleach (5% - 6% sodium hypochlorite) to the water.
Run the whirlpool for 5 to 10 minutes. Turn off the whirlpool and drain.
If desired, rinse the bath surfaces with water.
Rinse the surfaces of the jets, faucet, grab bars, and drain, and wipe them dry with a soft cloth.
Troubleshooting Procedures
NOTICE: This section is for general aid only. A Kohler Co. Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, call 1-800-4KOHLER from within
the USA and Canada, or 001-800-456-4537 from within Mexico.
NOTE: The product model number is printed on a label on the pump side of the whirlpool bath.
NOTE: For service parts information, visit your product page at www.kohler.com/serviceparts.
Troubleshooting the Whirlpool System
Symptoms Probable Causes Recommended Action
1. User keypad does not
illuminate when Power
icon is pressed or (if
applicable) the outer ring
is rotated.
A. No power to control. A. Check wiring and connect power.
B. GFCI tripped. B. Reset GFCI.
C. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
C. Check wiring for proper
connections. Replace wiring
harness if necessary.
D. User keypad does not work. D. Replace user keypad.
E. Control does not work. E. Replace control.
2. Motor starts, but all jets
are not functioning.
A. Jet is closed. A. Rotate jet trim counterclockwise to
open.
B. Jet not installed correctly. B. Reinstall jet; check for O-ring
damage.
C. Jets are blocked. C. Remove blockage.
3. User keypad is
illuminated, but does not
respond to icons or outer
ring.
A. Control program is locked. A. Reset GFCI.
B. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
B. Check wiring for proper
connections. Replace wiring
harness if necessary.
C. User keypad does not work. C. Replace user keypad.
D. Control does not work. D. Replace control.