Generator Set Dimensions and Weights
Overall Size, L x W x H: 777 x 712 x 824 mm
(30.6 x 28 x 32.4 in.)
Shipping Weight: 10RESV 194 kg (428 lb.)
12RESV 196 kg (433 lb.)
NOTE: Dimensions are provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
L W
H
G4-241 (10/12RESV) 3/15d
Additional RDC2 Controller Features
D Diagnostic messages
d Displays diagnostic messages for the engine, generator,
Model RXT transfer switch, programmable interface
module (PIM), and load control module (LCM)
d Over 70 diagnostic messages can be displayed
D Maintenance reminders
D System settings
d System voltage, frequency, and phase
d Voltage adjustment
d Measurement system, English or metric
D ATS status (Model RXT ATS required)
d Source availability
d ATS position (normal/utility or emergency/generator)
d Source voltage and frequency
D ATS control (Model RXT ATS required)
d Source voltage and frequency settings
d Engine start time delay
d Transfer time delays
d Voltage calibration
d Fixed pickup and dropout settings
D Programmable Interface Module (PIM) status displays
d Input status (active/inactive)
d Output status (active/inactive)
D Load control module (LCM) menus
d Load status
d Test function
Generator Set Standard Features
D Battery cables
D Critical silencer
D EPA certified fuel system
D Field-connection terminal block
D Fuel solenoid valve and secondary regulator
D Line circuit breaker:
10RESV: 50 amps
12RESV: 60 amps
D Multi-fuel system, LPG/natural gas, field-convertible
D Oil drain extension with shutoff valve
D OnCuer Plus Generator Management System
D RDC2 generator set/ATS controller
D Rodent-resistant construction
D Sound enclosure with sound-deadening, flame-retardant
foam per UL 94, class HF-1
D 5-year limited warranty
Available Accessories
Approvals and Listings
- CSA Approval (60 Hz only)
Concrete Mounting Pads
- Concrete mounting pad, 3 in. thick
- Concrete mounting pad, 4 in. thick
(recommended for storm-prone areas)
Available Accessories, Continued
Controller Accessories
- Programmable Interface Module (PIM)
(provides 2 digital inputs and 6 relay outputs)
- Load Control Module (LCM)
(provides 4 power relays and 2 HVAC relays)
Electrical System
- Battery
Fuel System
- Flexible fuel line
Maintenance
- Maintenance kit
Literature
- General maintenance literature kit
- Overhaul literature kit
- Production literature kit
Starting Aids
- Carburetor heater, 120 VAC (recommended for
reliable starting at temperatures below 0_C[32_F])
Kohlerr Automatic Transfer Switch
- Model RXT, see specification sheet G11-121
- Model RDT, see specification sheet G11-98
- Model RSB, see specification sheet G11-101
- Other Kohlerr ATS
Miscellaneous Accessories
- __________________________________________
- __________________________________________
* Accessories are available through Kohler authorized distributors and
dealers.
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-457-4441, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KOHLERPower.com
Kohler Power S ystems
Asia Pacific Headquarters
7 Jurong Pier Road
Singapore 619159
Phone (65) 6264-6422, Fax (65) 6264-6455