Installation Guide

7. Installation Checkout
Connect the drain tailpiece to the P-trap.
Using the key provided, remove the aerator from the spout.
If applicable, uncover the drain.
Turn on the main water supply and check for leaks. Adjust as
needed.
Allow the water to run through the spout for about 1 minute to
remove any debris. Check for leaks and adjust as needed.
Temporarily cover the sensors on the faucet or close the water
supplies.
Using the key provided, reinstall the aerator to the spout.
Uncover the sensors on the faucet or turn on the water supplies.
Troubleshooting
Symptoms Probable
Causes
Recommended Action
1. No water
flow.
A. Filter is
plugged.
A. Clean or replace the filter.
B. Sensor eyes
are dirty.
B. Wipe the sensor eyes with a
damp soft cloth. Wipe dry with a
dry soft cloth.
Aerator
Key
1124215-2-B 10 Kohler Co.