Installation Guide

4. Install AC Multi-Output Supply
Multiple Faucet Installations
Mount the AC supply under the counter using two (not supplied)
screws. Orient as shown.
Remove the cover.
Connect the faucet wire to the faucet.
If needed, cut and strip the AC supply wires to length.
Connect the stripped ends to the bottom terminal block (TB2) in
the supply box.
NOTE: If a hard wired installation is required, go to the next
installation section.
Plug the AC supply into the wall outlet.
Secure any excess wire under the counter.
IMPORTANT! The area in front of the sensor must be free of
objects during the two minute learning cycle or the faucet may not
function properly.
Allow two minutes for the sensor to cycle through the automatic
sensing distance.
AC Gang
Supply
Black
Red
AC Supply
1124215-2-B 6 Kohler Co.