Operating Guide

1. Water Temperature Adjustments
Use the following procedure to adjust the limit-temperature
locking-ring:
Pry off the plug button using a small flat-bladed screwdriver.
Loosen the setscrew and remove the lever handle.
Note the position of the outer locking-ring relative to the inner
geared-ring.
NOTE: Pry the locking-ring up equally at either side in order to
remove it from the valve.
Using a small flat-bladed screwdriver, pry up the outer
locking-ring.
Rotate the outer ring clockwise to increase temperature, or
counterclockwise to decrease temperature.
Align the geared teeth and slide the locking ring into position.
Place the lever handle back onto the assembly.
If desired, test the setting and repeat these steps in order to make
further adjustments.
When adjustments are complete, tighten the setscrew using the
supplied hex wrench.
Place the plug button in place.
Setscrew
Handle
Inner Geared
Ring
Locking
Ring
Plug Button
Inner Geared
Ring
Locking
Ring
1032027-5-B 4 Kohler Co.