Full Product Manual

TP-7092 4/23 23
1.8.5 Oil Pressure Sensor Boot Kit
The oil pressure sensor boot protects the oil pressure sensor and its connection from moisture and frost buildup that can cause
false low oil level faults. Install the oil pressure sensor boot in locations where the ambient temperature drops below 0°C (32°F).
See Figure 14 for illustrations of the installed kit. Follow the instructions provided with the kit to install the boot.
Figure 14 Oil Pressure Sensor Boot Location
1.8.6 Carburetor Heater
An optional carburetor heater is recommended for improved cold starting in locations where the ambient temperature drops
below 0°C (32°F). The carburetor heater prevents condensation and carburetor icing. The heater requires a continuous source
of AC power.
See the generator set Installation manual for more information.
Generator set model
Voltage
Thermostat ON
Thermostat OFF
14 kW Models
120 VAC
4 ± 3°C (40 ± 5°F)
16 ± 3°C (60 ± 5°F)
240 VAC
20 kW Models
120 VAC
4 ± 4°C (40 ± F)
16 ± 3°C (60 ± 5°F)
240 VAC
26 kW Models
120 VAC
4 ± 4°C (40 ± F)
16 ± 3°C (60 ± 5°F)
Figure 15 Heater Specifications
Figure 16 Carburetor Heater with Thermostat and Power Connectors, 14 kW Models
Oil pressure sensor boot
14 kW Models
GM102176
20 and 26 kW Models
Thermostat
120 VAC plug
GM19463
240 VAC 3-pin Mate-N-Lock
connector