Full Product Manual

70 TP-7092 4/23
4.2 Lubrication System
See the service schedules section for oil change and oil filter replacement intervals. See the service views section for the oil
drain, oil dipstick, oil fill, and oil filter locations.
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before working on the generator set. Remove the
negative () lead first when disconnecting the battery. Reconnect the negative ()
lead last when reconnecting the battery.
Disabling the generator set. Accidental starting can cause severe injury or death. Before working on the generator set or
equipment connected to the set, disable the generator set as follows: (1) Press the generator set off/reset button to shut down
the generator set. (2) Disconnect the power to the battery charger, if equipped. (3) Remove the battery cables, negative () lead
first. Reconnect the negative () lead last when reconnecting the battery. Follow these precautions to prevent the starting of the
generator set by the remote start/stop switch.
WARNING
Hot engine and exhaust system.
Can cause severe injury or death.
Do not work on the generator set until it cools.
4.2.1 Low Oil Pressure Shutdown
The low oil pressure (LOP) shutdown feature protects the engine against internal damage if the oil pressure drops below a
minimum pressure because of oil pump failure or other malfunction. See the Faults section for instructions if the generator set
shuts down on a fault.
Note:
The LOP shutdown feature does not protect against damage caused by operating when the oil level is low; it is not a low oil level
shutdown. Check the oil level regularly, and add oil as needed.