How To Guide

Product Information
Applicable product:
26 kW Fast-Response
®
steam
generator (qty of 2, 13 kW each)
K-1697
30 kW Fast-Response
®
steam
generator (qty of 2, 15 kW each)
K-1716
Water and drain requirements:
Water supply 3/8 line, 3/8 NPT female thread
Steam line 1/2 copper line 1/2 NPT female
thread
Pressure relief
valve
3/4 NPT male thread, valve
supplied
Generator Weight
Total:
26 kW, 30 kW = 64 lbs (29 kg)
Generator Electrical Rating
K-1697 (qty of 2,
13 kW each)
26 kW 240 V, 59 A, 50/60 Hz
K-1716 (qty of 2,
15 kW each)
30 kW 240 V, 68 A, 50/60 Hz
Required Electrical Service
Dedicated circuit required for each generator:
Steam generator K-1697 240 V, 80 A, 50/60 Hz
Steam generator K-1716 240 V, 90 A, 50/60 Hz
Installation Notes
Install this product according to the installation guide.
Fixture dimensions are nominal.
For this steam generator, enclosure shall not exceed the
maximum rating volume.
To determine the appropriate model for your installation,
determine the cubic feet of your steam area by multiplying L x
W x H. Compare the total to chart in the specification sheet
and use the closest match. Always round up. For every foot of
ceiling height over 8’ (2.45 m) use the next larger steam unit.
Steam
generator
model
Power Rating Max Volume Rating
K-1697 26 kW 894 cu. ft. (25 cu. m)
K-1716 30 kW 1000 cu. ft. (28 cu. m)
17-3/4" (45.1 cm)
Steam Outlet
Water Inlet
9-1/8"
(23.2 cm)
Minimum required access is 24" (61 cm) L x 15" (38.1 cm) H.
Allow for a minimum of 12" (30.5 cm) of space around
all sides of the steam generator.
Green LED
Diagnostic Light
12"
(30.5 cm)
12" (30.5 cm)
RJ-12
Control Jack
Field Wiring
Service Box
3/4" NPT
Pressure Relief
11-3/4"
(29.8 cm)
Roughing-In
K-1697, K-1716
STEAM GENERATOR
STEAM GENERATOR
1096627-1-
D

Summary of content (1 pages)