Specification

G4-246 (20RESC) 1/19d
RDC2 Controller
V oltage: 240 V
Freq: 60.0 Hz
The RDC2 controller provides integrated control for the
generator set, Kohlerr Model RXT transfer switch,
programmable interface module (PIM), and load shed kit.
The RDC2 controller’ s 2-line LCD screen displays status
messages and system settings that are clear and easy to read,
even in direct sunlight or low light.
RDC2 Controller Features
D Membrane keypad:
d OFF, AUTO, and RUN pushbuttons
d Select and arrow buttons for access to system
configuration and adjustment menus
D LED indicators for OFF, AUTO, and RUN modes
D LED indicators for utility power and generator set source
availability and ATS position (Model RXT transfer switch
required)
D LCD display:
d Two lines x 16 characters per line
d Backlit display with adjustable contrast for excellent
visibility in all lighting conditions
D Scrolling system status display:
d Generator set status
d Voltage and frequency
d Engine temperature
d Oil pressure
d Battery voltage
d Engine runtime hours
D Date and time displays
D Smart engine cooldown senses engine temperature
D Digital isochronous governor to maintain steady-state speed
at all loads
D Digital voltage regulation: 1.0% RMS no-load to full-load
D Automatic start with programmed cranking cycle
D Programmable exerciser can be set to start automatically on
any future day and time, and run every week or every two
weeks
D Exercise modes:
d Unloaded weekly exercise with complete system
diagnostics
d Unloaded full-speed exercise
d Loaded full-speed exercise (Model RXT ATS required)
D Front-access mini USB connector for SiteTecht or USB
Utility connection
D Integral Ethernet connector for Kohlerr OnCuer Plus
D Built-in 2.5 amp battery charger
D Remote two-wire start/stop capability for optional connection
of a Model RDT transfer switch
D Diagnostic messages:
d Displays diagnostic messages for the engine, generator,
Model RXT transfer switch, programmable interface
module (PIM), and load shed kit
d Over 70 diagnostic messages can be displayed
D Maintenance reminders
D System settings:
d System voltage, frequency, and phase
d Voltage adjustment
d Measurement system, English or metric
D ATS status (Model RXT ATS required):
d Source availability
d ATS position (normal/utility or emergency/generator)
d Source voltage and frequency
D ATS control (Model RXT ATS required):
d Source voltage and frequency settings
d Engine start time delay
d Transfer time delays
d Voltage calibration
d Fixed pickup and dropout settings
D Programmable Interface Module (PIM) status displays:
d Input status (active/inactive)
d Output status (active/inactive)
D Load control menus:
d Load status
d Test function
Generator Set Sound Data
Model 20RESC 8 point logarithmic average sound levels are
64 dB(A) during weekly engine exercise and 69 dB(A) during
full-speed generator diagnostics and normal operation. For
comparison to competitor ratings, the lowest point sound levels
are 62 dB(A) and 67 dB(A) respectively.*
All sound levels are measured at 7 meters with no load.
* Lowest of 8 points measured around the generator. Sound levels at
other points around generator may vary depending on installation
parameters.