Clean the Debris Filters
Retention Clips
Debris Filters
Connectors
CAUTION: Risk of personal injury. The valve may contain hot water. Be careful when draining any residual water.
Turn OFF the water supply to both inlets.
Start the shower for a few seconds to release trapped pressure and ensure that you have isolated the water supply.
Disconnect the power.
Unthread the screws to remove the covers.
Lift and remove the retention clips.
Remove the connectors. The O-ring and screen may be aached to the end of the connector.
If the screen remains in the connector, use a pair of needlenose pliers to remove the debris lters from the connectors.
Clean the debris lters to remove any dirt or debris.
NOTE: The check valve is located within the product and does not require routine servicing. If the check valve needs to
be replaced, use a blunt object to pull the check valve from the product and replace.
Reassemble the inlet connections.
Replace the covers. Secure with the provided screws.
1430528-2-A