Specification
Anthem
™
Six-port digital thermostatic valve
K-28212
2-7/16"
(62 mm)
8-1/4"
(210 mm)
5-13/16"
(148 mm)
9-1/16"
(230 mm)
19-13/16" (503 mm)
18-1/4" (464 mm)
3"
(76 mm)
3-7/16"
(87 mm)
1-15/16"
(49 mm)
9-9/16" (243 mm)
1/2" Outlet
Connection
1/2" Outlet
Connection
21-1/8" (537 mm)10-11/16 (271 mm)
Hot Inlet 3/4"
Connection
Cold Inlet 3/4"
Connection
Required Electrical Service
One circuit required, protected with Class A Ground-Fault
Circuit-Interrupter (GFCI). Outside North America, this device
may be known as a Residual Current Device (RCD).
Thermostatic valve: 120 V, 1.6 A, 60 Hz
Technical Information
All product dimensions are nominal.
Power source: Plug - AC, included
Shower Valve:
Flow Rate (Max) @ 45 psi 22.5 gal/min (85.2 l/min)
Manufacturer's minimum rated flow: 0.9 gal/min (3.4 l/min)
Pressure: 45 psi (3.1 bar)
Maximum (Static) Pressure: 125 psi (8.6 bar)
Minimum (Operating) Pressure: 15 psi (1 bar)
Valve body: Plastic
Drain included: No
Electrical component
rating:
Thermostatic valve: 120 V, 1.6 A, 60 Hz
Cable length: Data, 32 ft (9.8 m)
Bluetooth® range: 33 ft (10.1 m)
Bluetooth® version: 5.0
Max. Ambient temp: 122°F (50°C)
Min. Operating
temp:
34°F (1.1°C)
Max. Operating
temp:
122°F (50°C)
Pressure/fixture Supply Requirements
Fixture pressure
max (static):
145 psi (999.7 kPa)
Fixture pressure min
(static):
15 psi (103.4 kPa)
Min flowing
pressure:
15 psi (103.4 kPa)
Min flow rate: 0.9 gpm (3.4 lpm)
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
1-6-2022 12:02 - US/CA/MX