Specification

Overall Size, L x W x H, mm (in.): 1880 x 836 x 1169
(74 x 32.9 x 46.0)
Shipping Weight, wet, kg (lb.): 599 (1320)
Weight includes generator set with engine fluids, sound enclosure,
silencer, and packaging.
DISTRIBUTED BY:
Dimensions and Weights
NOTE: This drawing is provided for reference only and should not be
used for planning installation. Contact your local distributor for more
detailed information.
H
WL
2016 by Kohler Co. All rights reserved.
G4-229 (30RCL) 4/16
Additional RDC2 Controller Features
D Diagnostic messages
d Displays diagnostic messages for the engine, generator,
Model RXT transfer switch, programmable interface
module (PIM), and load management device
d Over 70 diagnostic messages can be displayed
D Maintenance reminders
D System settings
d System voltage, frequency, and phase
d Voltage adjustment
d Measurement system, English or metric
D ATS status (Model RXT ATS required)
d Source availability
d ATS position (normal/utility or emergency/generator)
d Source voltage and frequency
D ATS control (Model RXT ATS required)
d Source voltage and frequency settings
d Engine start time delay
d Transfer time delays
d Fixed pickup and dropout settings
d Voltage calibration
D Programmable interface module (PIM) status displays
d Input status (active/inactive)
d Output status (active/inactive)
D Load control menus
d Load status
d Test function
Generator Set Standard Features
D Aluminum sound enclosure with enclosed silencer
D Battery rack and cables
D Electronic, isochronous governor
D Flexible fuel line
D Gas fuel system (includes fuel mixer, electronic secondary
gas regulator, two gas solenoid valves, and flexible fuel line
between the engine and the skid-mounted fuel system
components)
D Integral vibration isolation
D Line circuit breaker
D Oil drain extension
D OnCuer Plus Generator Management System
D Operation and installation literature
D RDC2 controller with built-in battery charger
D Standard five-year or 2000 hour limited warranty
Available Options
Approvals and Listings
- UL 2200/cUL Listing (60 Hz only)
- CSA Approval (60 Hz only)
Controller Accessories
- Programmable Interface Module (PIM)
(provides 2 digital inputs and 6 relay outputs)
Electrical System
- Battery
- Battery Heater
Available Options, Continued
Starting Aids w
- Block Heater, 120 V, 1 Ph
- Block Heater, 240 V, 1 Ph
- Oil P an Heater, 120 V, 1 Ph
- Oil P an Heater, 240 V, 1 Ph
w One block heater or oil pan heater is recommended for ambient
temperatures below 0C(32F). At temperatures below -18C(0F),
installation of both heaters is recommended.
Automatic Transfer Switches and Accessories
- Model RDT Automatic Transfer Switch
- Model RXT Automatic Transfer Switch
- Model RXT A utomatic Transfer Switch with Combined
Interface/Load Management Board
- Load Shed Kit for RDT or RXT
- Power Relay Modules (use up to 4 relay modules for each
load management device)
Miscellaneous
- Rated Power Factor Testing
Literature
- General Maintenance Literature Kit
- Overhaul Literature Kit
- Production Literature Kit
Warranty
- Extended 5-Year/2000 Hour Comprehensive Limited Warranty
Other Options
- _______________________________________________
- _______________________________________________