Installation Guide

4. Route the Cables
Power Outlet
Transducer Wires
Chromatherapy Cable
Chromatherapy
Cable (If Equipped)
Transducer
User Interface Cable
Ethernet Connector
User Interface
IMPORTANT! Sev
eral included bath components will be powered by the control amplier with 25' (7.6 m) cables. Plan
the location of the control amplier so the cables will reach without being under tension.
Carefully cut the cable tie securing the coiled transducer wires to the bath.
Route the transducer wires through the framing to the control amplier location, drilling 1" (52 mm) holes where
needed.
If equipped with chromatherapy, route the chromatherapy cable from the bath to the control amplier location. Follow
the same route as the transducer wires.
Route the user interface cable through the framing from the user interface location to the control amplier location.
Make sure that the larger Ethernet-style connector is at the control amplier end. Include a drip loop.
If used, route an auxiliary-in cable (not included) to the control amplier location.
Kohler Co. 11
1297608-2-E