Installation Guide

Symptoms Probable Cause Recommended Action
3. Chromatherapy lights
remain locked on one
color.
A. Control amplier must be
reset.
B. User interface does not
work properly.
C. Chromatherapy or user
interface cable connections
are loose or damaged.
D. If none of the
recommended actions
correct the problem,
contact Kohler Co.
A. Unplug the amplier power supply from the electrical
outlet. Wait 30 seconds, then plug in the power supply
and restart.
B. Cycle through the chromatherapy light functions. If the
lights do not cycle through all colors and the blue icon
on the user interface is not lit, replace the user
interface.
C. Inspect the cables for loose connections or damage.
Replace the cables as needed.
D. Contact the Customer Care Center for assistance.