Installation Guide

3. Install the Vanity
Back Rail
Leveler
Washer
Lag Bolt
Pilot Hole
DANGER: Risk of electric shock. To reduce the risk of electrical shock, connect only to circuits protected by a
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
CAUTION: Risk of personal injury or property damage. Select 250 lb (113.4 kg) load-bearing 5/16" lag bolts with a
length to clear obstacles in the wall and 5/16" washers. Calculate the proper lag bolt length by adding the following:
1-1/2" (38 mm) backing material, plus the wallboard thickness, plus the back rail thickness.
CAUTION: Risk of product damage. Drill the lag bolt pilot holes near the ends of the back rail to provide
maximum support and to prevent exing of the vanity.
With assistance, lift and place the cabinet in position against the nished wall. Do not slide or side-load the legs.
If the vanity has an electrical outlet, route the electrical cord to the GFCI-protected, 120 V, 15 A, grounded electrical
outlet.
Verify that the vanity is level and plumb against the wall. If necessary, turn the levelers to adjust the unit.
Using a 1/4" drill bit, drill a pilot hole through each end of the back rail and into the nished wall. Verify that the holes
align with the 2x6 support or a wall stud.
Secure the vanity to the wall with 5/16" lag bolts and washers (not provided). The lag bolts should engage the 2x6
bracing or a wall stud.
If the vanity has an electrical accessory component, plug the electrical cord into a GFCI-protected, 120 V, 15 A,
grounded electrical outlet.
1551656-2-A