OnCue Plus Spec Sheet

G6-179 (OnCuer Plus) 1/21
System Requirements
D Personal computer (PC) requires one of these Internet
browsers :
d Google Chrome
d Apple Safari
d Microsoft Edge 79+
d Firefox
D Mobile devices require Androidt 5.0 or higher or iOS 11.0 or
higher
D Always-on Internet access for the generator (for example,
cable, DSL, or phone line modem connected 24 hours a day)
D Amazon Alexa or Google Assistant application on smart
devices to access voice control (optional)
D OnCue Plus wireless k it (optional)
D Uninterruptible power supply (UPS) for modem and router
(optional)
D See the connection diagrams for customer-provided cables
and equipment
Wireless Bridge Specifications
D Environmental specifications:
d Operating temperature: - 30 to 55_C (- 22 to131_F)
d Storage temperature: - 40 to 70 _C(-40to158_F)
d Humidity: 5% to 95% (typical)
d Waterproof level IP65
D Dimensions. L x W x H: 168 x 88 x 48 mm (6.6 x 3.5 x 1.9 in.)
D RF Frequency: 5.150- 5.850 GHz
D Regulatory Compliance:
d CE-LVD
d EN 60950-1:2006 + A1: 2009 + A1: 2010 + A12: 2011 +
A2: 2013
d IEC 60950-1: 2005 +A1: 2009 + A2: 2013
D Protocol/Standard
d IEEE 802.3 (Ethernet)
d IEEE 802.3u (Fast Ethernet)
d IEEE 802.11b/g/n/ac
D Power Specification:
d DC PoE: 24 VDC @ 0.5A
D Wireless Bridge Operating Specifications:
d Voltage 100- 240 VAC
d Frequency 50- 60 Hz
d Input current 300 mA max. @ 90 VAC min.
D LEDs for power and network connection status
View System Operation Data
Generator Set
D Home is powered by the generator or utility power
D Generator set status: running, standby, shutdown, or off
D Active fault indication
D Generator voltage
D Engine starting battery voltage, VDC
D Frequency, Hz
D Generator event history
D Event details, including description, time, and date
D Exercise type
D Next scheduled exercise date and time (estimated based on
last exercise date and time)
D Over 20 different parameters
D Generator power, in kW (LCM required*)
D Engine hours
D Last exercise date and time
D Exercise interval, duration and mode
Load Manag ement *
D Loads are added or shed automatically based on generator
load
D View connected loads
D On/Off indicators for each circuit indicate status (powered or
shed)
D Change load labels to identify the connected circuits
Programmable Interface Module (PIM) [
D View relay status
D On/Off indicators show connected circuits
D Change input and output labels to identify connected circuits
6VSG Communications Kit
D View input and output status
D On/Off indicators show connected circuits
* Model RXT automatic transfer switch and Load Control Module (LCM), load shed kit, or combined interface/ load management board can be used with
generator sets equipped with the RDC2 or DC2 c ontroller.
[ PIM can be used with generator sets equipped with the RDC2, DC2, or VSC c ontroller.