4. Install the Steam Generator
WARNING: Risk of property damage. Allow a minimum of 12 (305 mm) of air space around the
steam generator at all times. This provides an area for the heat generated by the unit to dissipate.
NOTICE: For optimum performance, install the steam generator as close as possible to the steam head.
The steam generator must be installed within 25’ (7.62 m) of the steam head.
Install the desired drain pan at the steam generator location. Kohler Co. recommends using a
KOHLER drain pan.
IMPORTANT! If a KOHLER drain pan is NOT being used, construct the support blocks using
heat-resistant material.
Position the steam generator on the support blocks.
Steam Outlet
Water Inlet
Pressure
Relief Valve
Drain Pan
Control
Cable
Input
3/4"
(19 mm)
Min
Drain (install per
applicable codes.)
12"
(305 mm)
Single Installation Dual Installation
Maintain a 12" (305 mm)
minimum space around
the units.
1230487-2-C 10 Kohler Co.