User's Manual

TP-5695 12/93 Installation 6-9
TOTAL HOURS
00 000
1/10
10A
FUSE
BATT.
CHRG.
INPUT
NOTE
Usetwohoseclampsoneach
end of all flexible exhaust
hose connections.
1. Exhaust Manifold
2. 3 ft. (1 m) Max.
3. Engine-Driven Seawater Pump
4. Heat Exchanger
5. Waterline
6. Seawater Strainer
7. Intake Strainer
8. Engine Coolant
9. Seawater
10. Seacock
11. Coolant Recovery Tank
1
2
3
4
5
6
7
8
9
10
11
STOP/START
258000-D
Figure 6-15. Closed/Heat Exchanger Cooling System
Exhaust Systems
General
Water-cooledexhaustlinesshouldbeusedin all marine
installations. The hose used for the lines should have a
2 in. (51 mm) inside diameter. Keep the lines as short
andstraightas possible. The useoftwohose clamps on
each end of flexible exhaust hose connections is highly
recommended. ABYC Safety Standards P-1.6.c
recommend a pitch of at least 1/2 in. (12.8 mm) per
running foot (30.5 cm). Use flexible steam hose
conforming to UL Standard 1129 for Engine wet
exhaust components between the mixing elbow and
the exhaust outlet. A silencer should be independently
mounted to eliminate any stress on the exhaust system
and exhaust manifold/mixer elbow. See Figure 6-16 for
the exhaust connection to the mixer elbow.
1
1-894
1. Seawater/Exhaust Outlet
Figure 6-16. Mixer Elbow/Exhaust Connection