Installation Guide

10. Installation Checkout
Using the key provided, remove the aerator from the spout.
If applicable, uncover the drain.
Turn on the water supply and check for leaks. Adjust as needed.
Allow the water to run through the spout for about 1 minute to
remove any debris. Check for leaks and adjust as needed.
Temporarily cover the sensor on the faucet or close the water
supplies.
Using the key provided, reinstall the aerator to the spout.
Uncover the sensors on the faucet or turn on the water supplies.
Troubleshooting
Symptoms Probable Causes Recommended Action
1. No water flow. A. No power supply
or wrong
connection.
A. Check the power supply
and connection.
B. Object in sensing
range.
B. Remove the object.
C. Sensor eyes are
dirty.
C. Wipe the sensor eyes
with a damp soft cloth.
Wipe dry with a dry soft
cloth.
Kohler Co. 13 1377340-2-A